Alstom MV Drives Specifications

Alstom medium voltage drives technical data:

Alspa VDM5000
Topology 2-level Voltage Source Inverter
Input section Diode/SCR 6-, 12-, 18- pulse rectifier; HV IGBT with Active Energy Management
Input voltage 2300-4160V
Efficiency no data
Input power quality 6-pulse rectifier doesn’t meet IEEE 519 requirements, 12-pulse IEEE 519 compliance – In/Isc ratio dependent, 18-pulse and AFE meets IEEE 519; PF>0.97 at rated load
DC link section common DC link capacitors
Output section HV IGBT 2-level VSI
Converter power 1.4-7.2MVA
Output voltage 0-2300V, 0-3300V, 0-4160V
Output frequency max 130Hz
Field weakening 5:1 for synchronous motor, 3:1 for induction motor
Switching frequency no data
Output waveform 3-level line-to-line voltage waveform, high dv/dt
Motor type induction or synchronous
Overload no data
Cooling liquid
Control scheme FOC
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time 2-8ms
Torque accuracy no data
Modulation technique no data
Special features -
Alspa VDM6000
Topology 4-level Flying Capacitor Voltage Source Inverter
Input section Diode/SCR 6-, 12-, 18- pulse rectifier; HV IGBT with Active Energy Management
Input voltage 4160V – air cooled, 3300V water cooled
Efficiency >98%, >96.5% with isolation transformer
Input power quality 6-pulse rectifier doesn’t meet IEEE 519 requirements, 12-pulse IEEE 519 compliance – In/Isc ratio dependent, 18-pulse and AFE meets IEEE 519; PF>0.97 at rated load
DC link section common DC link capacitors + 2 isolated capacitors per phase
Output section HV IGBT 4-level flying capacitor VSI
Converter power 0.3-3MVA air cooled, 2.2-8MVA water cooled
Output voltage 0-2300V, 0-3300V, 0-4160V
Output frequency 60Hz air-cooled, 130Hz water-cooled
Field weakening 5:1 for synchronous motor, 3:1 for induction motor
Switching frequency no data
Output waveform 7-level line-to-line voltage waveform
Motor type induction or synchronous
Overload variable torque: 110% FLC for 60s (10% duty cycle); constant torque: 150% FLC for 60s (10% duty cycle)
Cooling air, water
Control scheme FOC
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time 2-8ms
Torque accuracy no data
Modulation technique no data
Special features -
Alspa VDM7000
Topology 3-level Neutral Point-Clamped Voltage Source Inverter
Input section Diode/SCR 6-, 12-, 18- pulse rectifier; GTO with Active Energy Management
Input voltage 3300V
Efficiency no data
Input power quality 6-pulse rectifier doesn’t meet IEEE 519 requirements, 12-pulse IEEE 519 compliance – In/Isc ratio dependent, 18-pulse and AFE meets IEEE 519; PF>0.97 at rated load
DC link section 2 capacitors
Output section GTO 3-level NPC VSI
Converter power 7-9.5MVA
Output voltage 0-3300V
Output frequency 60Hz
Field weakening 5:1 for synchronous motor, 3:1 for induction motor
Switching frequency no data
Output waveform 5-level line-to-line voltage waveform
Motor type induction or synchronous
Overload no data
Cooling water
Control scheme FOC
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time 2-8ms
Torque accuracy no data
Modulation technique no data
Special features -
Alspa CDM8000
Topology Current Source Inverter
Input section SCR 6-, 12- pulse rectifier; GTO with Active Energy Management
Input voltage up to 10kV
Efficiency no data
Input power quality 6-pulse rectifier doesn’t meet IEEE 519 requirements, 12-pulse IEEE 519 compliance – In/Isc ratio dependent, AFE meets IEEE 519; PF – no data, adjustable at rated load
DC link section DC link reactor
Output section PWM CSI
Converter power 5-8MVA for 6kV, 8.3-13.5MVA for 10kV
Output voltage 0-6000V, 0-10000V
Output frequency max. 240Hz
Field weakening 1.2:1
Switching frequency no data
Output waveform PWM motor current smoothed by output capicators
Motor type induction
Overload no data
Cooling air, water
Control scheme FOC
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time <20ms
Torque accuracy no data
Modulation technique no data
Special features dv/dt<20V/µs at 200Hz and motor voltage 10kV
Alspa SD7000
Topology Load Commutated Inverter
Input section SCR 6-, 12-, 24- pulse rectifier
Input voltage up to 10kV
Efficiency no data
Input power quality 6-pulse rectifier doesn’t meet IEEE 519 requirements, 12-pulse IEEE 519 compliance – In/Isc ratio dependent, 24-pulse meets IEEE 519; PF – varying with the load – reactive power compensation is necessary
DC link section DC link reactor
Output section SCR 6-, 12-, 24- pulse load commutated inverter
Converter power 2-10MVA for air cooled drive, 5-100MVA for water cooled drive
Output voltage 1000-10000V
Output frequency 100Hz
Field weakening 1.1:1
Switching frequency load commutation
Output waveform high output current harmonics resulting torque pulsations especially for 6-pulse inverters
Motor type synchronous
Overload no data
Cooling air, water
Control scheme no data
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time no data
Torque accuracy no data
Modulation technique load commutation
Special features high efficiency
Alspa CL9000
Topology Cycloconverter
Input/output section 3 antiparallel SCR 6- pulse converters
Input voltage 2300-13800V with transformer
Efficiency no data
Input power quality low supply harmonics – 18-pulse, PF is a function of speed
DC link section no DC link
Converter power 2-12MVA for air cooled drive, 5-100MVA for water cooled drive
Output voltage 1-4kV air cooled, 1-5kV water cooled
Output frequency 20Hz (600RPM, 4-pole motor) for 50Hz supply voltage 24Hz (720RPM, 4-pole motor) for 60Hz supply voltage
Field weakening 5:1 for synchronous motor, 3:1 for induction motor
Switching frequency natural commutation
Output waveform no data
Motor type synchronous or induction
Overload no data
Cooling air, water
Control scheme no data
Dynamic speed error no data
Steady-state speed error 0.5% without encoder, 0.01% with encoder
Torque response time no data
Torque accuracy no data
Modulation technique natural commutation
Special features low speed, high torque applications

References:

  1. ALSPA Drive Range. Drive solutions for all applications
  2. Innovative Medium Voltage Drives. ALSPA VDM/CDM
  3. Medium Voltage Drive. ALSPA CDM 8000
  4. Symphony. Air Cooled Medium Voltage AC Drives
  5. Update of product information brochure. Symphony – Air Cooled Medium Voltage AC Drives – ALSPA VDM6000A

Leave a Reply

You must be logged in to post a comment.